Authors reported previously how to measure s-triazolo [3,4-a] phthalazine which formaldehyde and 1-hydrazinopthalazine react and produced by HPLC with a fluorescence detector. The post column fluorescence derivatization method was examined in order to raise improvement in measurement accuracy in this time. The formaldehyde in indoor air is sampled for 60 minutes using passive sampler. Subsequntly, formaldehyde in collection medium is extracted with water. The derivative which the formaldehyde in an extract and 1,3-cyclohexanedione react and produce is measured by HPLC with fluorescence detector.
机译:撰写的报告以前如何测量甲醛和1-肼基丙嗪的S-Tri唑[3,4-A]酞嗪反应并通过HPLC与荧光检测器产生的反应。检查后柱荧光衍生化方法,以提高这一次测量精度的提高。使用被动采样器采样室内空气中的甲醛60分钟。然后,用水萃取收集培养基中的甲醛。用HPLC用荧光检测器测量萃取物和1,3-环己二酮反应和产生的甲醛的衍生物。