首页> 外文会议>ASME Turbo Expo >COMPARISON OF VARIOUS TUBE TO HEADER ATTACHMENT DETAILS UNDER CYCLE SERVICE
【24h】

COMPARISON OF VARIOUS TUBE TO HEADER ATTACHMENT DETAILS UNDER CYCLE SERVICE

机译:各种管与循环服务下的报头附件细节的比较

获取原文

摘要

Heat recovery steam generator (HRSG) superheater outlet headers are exposed to cyclic stresses under varying transient operating conditions. Three different tube to header connections are analyzed. Cold, warm, and hot startup cycles are defined along with a load change cycle. These cycles are used to develop boundary conditions for a transient three dimensional finite element analysis of each detail. The results show that the highest stresses are away from the tube to header weld area. For the startup cycles analyzed, equations are presented for cycle life determination.
机译:热回收蒸汽发生器(HRSG)过热器出口移位在不同的瞬态操作条件下暴露于循环应力。分析了三个不同的管与头部连接。冷,温暖和热启动周期与负载变化周期相同。这些循环用于开发每个细节的瞬时三维有限元分析的边界条件。结果表明,最高应力远离管焊接区域。对于分析的启动循环,提出了循环寿命确定的方程。