The cryogenic system of EAST (Experimental Advanced Superconducting Tokamak) facility has been put into operation for fourteen experimental campaigns since the first commissioning in 2005, which provides the adequate cooling power to keep the cold components of EAST Tokamak in the superconducting status. Its reliability directly influences the long time safe and steady operation of the Tokamak device. Through these years' operation, the process control flow and operational modes have been determined eventually. According to the ITER RAMI analysis approach, the fault modes of the EAST cryogenic system as well as the corresponding effects and criticality have been analyzed and assessed for its safety. The risk mitigation actions were also presented and implemented for future operation and maintenance to archive the goal of enhancing the reliability of the EAST cryogenic system.
机译:自2005年首次调试以来,东部(实验先进超导Tokamak)设施的低温系统已经投入了十四个实验活动,这提供了足够的冷却能力,以使东托卡马克的冷却部件保持在超导状态。它的可靠性直接影响了Tokamak设备的长时间安全和稳定运行。通过这些年的操作,最终确定了过程控制流程和操作模式。根据ITER Rami分析方法,已经分析了东部低温系统的故障模式以及相应的效果和临界性,并评估其安全性。还为未来的运营和维护提供了风险缓解行动,以归档提高东部低温系统可靠性的目标。