首页> 外文会议>International Conference on Power Electronics and ECCE Asia >Measurement of inverter caused losses in permanent magnet synchronous machines using a modular multiphase multilevel converter
【24h】

Measurement of inverter caused losses in permanent magnet synchronous machines using a modular multiphase multilevel converter

机译:使用模块化多相多级变频器测量永磁同步机中永磁同步机的损耗

获取原文

摘要

Current distortion of two-level converter-fed permanent magnet synchronous machines causes additional machine-side losses, which lead to a distinct reduction in the drive train efficiency of electric vehicles for instance. Determining these losses by measurement is still an ambitious task. On the one hand, there's a lack of adequate voltage sources. On the other hand, there is no accurate procedure to distinguish between the different loss components. In this publication, a 100 kVA seven-level multilevel converter is used to determine the losses of a 60 kW highly-utilized permanent magnet synchronous machine for automotive use. Due to the good voltage quality of the multilevel converter, the machine currents have very low harmonic distortion and the determined losses are considered as fundamental ones. In a second experiment, the machine is operated with a conventional two-level converter. Comparing machine losses in both experiments allows the determination of the additional machine losses in two-level operation.
机译:两级转换器馈电永磁同步机的电流失真导致额外的机器侧损耗,这导致电动车辆的传动系效率明显降低。通过测量确定这些损失仍然是一个雄心勃勃的任务。一方面,缺乏足够的电压源。另一方面,没有准确的过程来区分不同的丢失组件。在本出版物中,使用100 kVA七级多电平转换器来确定用于汽车使用的60 kW高度利用的永磁同步机的损耗。由于多级转换器的良好电压质量,机器电流具有非常低的谐波失真,并且所确定的损耗被认为是基本的。在第二个实验中,用传统的双层转换器操作机器。比较两种实验中的机器损耗允许在两级操作中确定额外的机器损耗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号