A new nanocomposite material, consisting of nanoiron incorporated in cationic resin beads, was evaluated for the removal of Cr(VI)under flow conditions, by conducting column experiments. An aqueous solution containing Cr(VI)5 mg/L and NaCl 0.01 M as inert electrolyte was introduced in the column applying a continuous up-flow mode. The tests were carried out using a column with diameter 2.6 cm and the flowrate was stepwise increased, reducing the Empty Bed Contact Time (EBCT)from 38 to 2.3 minutes. The reduction of Cr(VI)was found to depend on the residence time of the solution inside the bed of R-nFe, and the pH of flowing solution. The column has treated an amount of solution equivalent to 640 bed volumes without appearance of the Cr(VI)breakthrough. Also, when the feeding solution was spiked with both Cr(VI)and Ni, the effluents were free from the two elements, indicating that the nanocomposite material can be equally efficient in the case of mixed contamination.
机译:通过在流动条件下,评价由纳米铁掺入的新纳米复合材料,该材料由阳离子树脂珠粒组成,通过进行柱实验去除流动条件下的Cr(VI)。在施加连续上流模式的柱中引入了含Cr(VI)5mg / L和NaCl 0.01M的水溶液。使用直径为2.6cm的柱进行测试,逐步增加流量,从38至2.3分钟降低空床接触时间(EBCT)。发现Cr(VI)的还原取决于R-NFE床内的溶液的停留时间,以及流动溶液的pH。该柱对640床体积的溶液处理过的溶液,而不出现Cr(VI)突破。而且,当用Cr(VI)和Ni掺入饲料溶液时,流出物不含两种元素,表明在混合污染的情况下,纳米复合材料可以同样有效。