首页> 外文会议>Annual IEEE Applied Power Electronics Conference and Exposition >IPM synchronous machine drive response to a single-phase open circuit fault
【24h】

IPM synchronous machine drive response to a single-phase open circuit fault

机译:IPM同步机驱动响应单相开路故障

获取原文
获取外文期刊封面目录资料

摘要

This paper investigates the steady-state and dynamic response of an interior permanent magnet (IPM) synchronous machine drive to a single-phase open circuit fault. This fault results in rotational electromagnetic asymmetry on both the stator and rotor, making it difficult to analyze using classical dq-transformation techniques. This paper presents a new dq synchronous-frame machine model that is capable of handling this highly asymmetrical fault condition, including the effects of q-axis magnetic saturation. Fault responses with two alternative post-fault control strategies are investigated: (1) opening all of the inverter switches so that the machine behaves as an uncontrolled generator (UCG), with the two unfaulted phases connected to the inverter DC link via the anti-parallel diodes; and (2) shorting the two remaining unfaulted phases together using the inverter switches. Results of this investigation show that the fault response is generally more benign using the UCG control strategy, with significantly lower phase currents and pulsating torque than corresponding values delivered using the phase-shorting strategy.
机译:本文研究了内部永磁体(IPM)同步机驱动到单相开路故障的稳态和动态响应。该故障导致定子和转子上的旋转电磁不对称,使得难以使用经典DQ变换技术进行分析。本文介绍了一种新的DQ同步帧机模型,能够处理这种高度不对称的故障状况,包括Q轴磁饱和度的影响。研究了具有两个替代故障后控制策略的故障响应:(1)打开所有逆变器开关,以便机器表现为不受控制的发电机(UCG),两个未通过反相器直流链路连接到逆变器直流链路的相位。平行二极管; (2)使用逆变器开关缩短两个剩余的左右阶段。该研究结果表明,故障响应通常使用UCG控制策略更加良性,具有明显低于使用相位短路策略传送的相应值的相电流和脉动扭矩。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号