Indoor environmental monitoring of residential buildings in Saudi Arabia, Makkah: a case study

机译:沙特阿拉伯住宅建筑室内环境监测,麦加 - 案例研究

获取原文

摘要

In Saudi Arabia, buildings require significant amounts of energy, especially during the cooling season, because of excessive air conditioning demands related to the high outdoor temperatures. Residential buildings consume more than 50% of electricity in the Kingdom of Saudi Arabia, where air conditioning loads represent 70% of the consumption. The main aim of the paper is to improve indoor thermal performance of existing residential buildings in Saudi Arabia, using Makkah as a case study. The methodology is to choose typical low-rise residential buildings to evaluate indoor thermal performance of existing residential buildings in Makkah, then calibrate this with the simulated results taken from thermal analysis software (TAS) to validate them, finally adding few energy efficiency measures to decrease the cooling load in the case study building. The result is expected to show similarity between the two results and also indicate that the energy conservation measures used can decrease the cooling load to as high as 34.5%.
机译:在沙特阿拉伯,建筑物需要大量的能量,特别是在冷却季期间,因为与高户外温度有关的空调需求过高。住宅建筑在沙特阿拉伯王国消耗超过50%的电力,空调负荷占消费量的70%。本文的主要目的是提高沙特阿拉伯现有住宅建筑的室内热性能,以利用Makkah为例。该方法是选择典型的低层住宅建筑,以评估Makkah现有住宅建筑的室内热性能,然后通过从热分析软件(TAS)采取的模拟结果进行校准,以验证它们,最终增加了一些能源效率措施来减少案例研究建筑中的冷却负荷。预计结果将在两种结果之间表现出相似性,并且还表明所用的节能措施可以将冷却载荷降低到高达34.5%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号