The advantage of using computational methods to evaluate the overhead-line temperature in conjunction with high-definition thermography is analysed. A high-current-carrying transmission line served as a test site to monitor the temperature of the conductor and an overheated joint. A computational method is used to assess the conductor temperature from the operating current, the wind speed and direction, and the outdoor temperature. The technique involves determining the difference between the temperature evaluated from simulations and the actual measured temperature. Once this difference is known, the operating parameters on the thermographic system are adjusted to get a valid temperature on the conductor within a certain probability factor. On the basis of these results, an attempt is made to evaluate the joint temperature from thermographic information on the conductor next to the joint. Plausible explanations for the observed differences and difficulties are discussed.
机译:分析了使用计算方法评估与高清热成像结合高度线温度的计算的优点。一种高电流承载传输线作为测试部位,以监测导体的温度和过热的接头。计算方法用于评估来自工作电流,风速和方向和室外温度的导体温度。该技术涉及确定从仿真和实际测量温度评估的温度之间的差异。一旦知道这种差异,就会调整热敏系统上的操作参数以在一定概率因子内获得导体上的有效温度。在这些结果的基础上,尝试评估来自关节旁边的导体上的热敏信息的关节温度。讨论了观察到的差异和困难的合理解释。