摘要

The results of measurements and modelling of nonlinear low level leakage currents (LC) that appear on surfaces of nonceramic insulators are presented. Two possible causes for the non-linearity are discussed, i.e. (i) the formation of a dry band on a hydrophilic surface and (ii) water droplet deformation on a partially hydrophobic surface. These effects are separately evaluated in two sets of LC measurements on polluted polymeric surfaces during a hydrophobicity recovery process with continuous ACvoltage and half wave AC pulses. In each case, model circuits (RC components) are adopted. Attempts are also made to estimate and optimise values for these RC components.
机译:介绍了在非线性绝缘体表面上出现的非线性低级漏电流(LC)的测量结果和建模。讨论了非线性的两个可能原因,即(i)在亲水表面上形成干燥带和(ii)在部分疏水表面上的水滴变形。在具有连续式ACV电压和半波AC脉冲的疏水性回收过程中,在疏水性恢复过程中分别在两组LC测量中分别评估这些效果。在每种情况下,采用型号电路(RC组件)。还尝试估计和优化这些RC组件的值。