A noise and vibration annoyance problem has existed for some time in an office and conference facility at a major industrial plant site. Vipac Engineers & Scientists were engaged to investigate the problem and recommend appropriate treatments foran engineering solution.A large multi-storey industrial plant (IP) building on the site contains a moving tripper and a series of vibratory feeders and vibratory screens in addition to conveyers and storage bins. The office/conference (OC) building is situated about 150 metres from the P building. The intervening land is flat and predominantly covered in asphalt with no substantial obstacles along the line-of-sight. In addition, there is a large overhead conveyor system that passes about 10 metres above the OC building.Workers in the OC building, particularly users of the Conference Room, have been complaining of unusually high or annoying levels of vibration (primarily rattling of ceiling panels) and noise (affecting comfort and communication).
机译:在一个主要的工业工厂网站的办公室和会议设施中存在噪音和振动烦恼问题。 VIPAC工程师和科学家们从事调查该问题,并建议使用适当的护理工程解决方法。除了输送机外,站点上的大型多层工业厂房(IP)建筑物还包含一系列移动的TREGPER和一系列振动饲养器和振动筛网存储箱。办公室/会议(OC)大楼距离P建筑约有150米。介入的土地是平坦的,主要覆盖在沥青中,沿着视线没有大量障碍。此外,还有一个大型架空输送系统,在OC建筑物上方大约10米。OC建筑物的工作人员,特别是会议室的用户,一直抱怨异常高或令人讨厌的振动水平(主要是天花板的咆哮)和噪音(影响舒适和通信)。