Performance Optimization of a Fan System Overcoming Impacts of Modified Design Criteria Due to Regulatory Requirements and Changed Operating Conditions

机译:由于监管要求和改变操作条件,克服改进设计标准的风扇系统的性能优化克服了改进的设计标准的影响

获取原文
获取外文期刊封面目录资料

摘要

The Louisiana Pacific mill in Tomahawk Wisconsin manufactures oriented-strand board. Several large induced-draft fans and combustion-air blowers were operating inefficiently at this mill. this case study highlights a systems approach that was applied to address fan inefficiency. Energy savings from optimizing the system are estimated to be 338 kW, nearly half of the original measured input power of 678 kW. The project is currently being implemented and will have a payback period of less than 8 months. The opportunities here are typical of opportunities thought to exist in most industrial plants. In this case, process needs changed due to environmental regulations and change of location, but the system did not, leading to low overall system efficiency.