首页> 外文会议>IMEKO World Congress >INFLUENCE OF THERMAL CONTACT RESISTANCE IN THERMAL CONDUCTIVITY MEASUREMENTS USING GUARDED HOT PLATE METHOD
【24h】

INFLUENCE OF THERMAL CONTACT RESISTANCE IN THERMAL CONDUCTIVITY MEASUREMENTS USING GUARDED HOT PLATE METHOD

机译:防护热板法测定热敏接触电阻的影响

获取原文

摘要

A new technique was developed at the Hungarian Metrological Institute (MKEH), devoted to optimising the thermal conductivity measurements by quantifying and minimising the effect of the thermal contact resistance (TCR) arising between a rigid sample and the heated plate of a high temperature guarded hot plate. Due to the existence of the TCR, the calculated thermal conductivity, based on different measurement techniques, could differ with by as much as 5-9 %. The work was performed in the frame of the European Metrology Research Program (EMRP SIB52) titled "Metrology for Thermal Protection Materials".
机译:在匈牙利的计量研究所(MKEH)中开发了一种新的技术,致力于通过量化和最小化刚性样品和高温焊接热的加热板之间产生的热接触电阻(TCR)的效果来优化导热率测量盘子。由于TCR的存在,基于不同的测量技术计算的导热率可能与5-9%不同。该工作是在欧洲计量研究计划(EMRP SIB52)的框架中进行的,标题为“热保护材料的计量”。