Measurement of Arterial Young's Elastic Modulus using ARTSENS Pen

机译:使用Artsens Pen的动脉杨氏弹性模量测量

获取原文
获取外文期刊封面目录资料

摘要

Arterial Young's modulus (Y) is an important elastic property of the artery that quantifies the material stiffness. Several studies have demonstrated that the quantitative values of Y and its standard deviation could be potentially used as an independent predictor of coronary heart diseases. For reliable measurements of Y, accurate measurements of arterial diameter and wall thickness are required. Conventionally these arterial dimensions are measured by imaging systems that are not a viable option for large-scale screening due to their form factor and a high degree of complexity. In this work, we present a portable image-free ultrasound modality - ARTSENS Pen for measurement of Y. ARTSENS is an extensively validated technology that is capable of providing clinical standard measurements of arterial dimensions and stiffness. In this present work, we have demonstrated the capability of the ARTSENS to make accurate and repeatable measurements of Y. The performance of the device is validated through an in-vivo study on 15 subjects. The ARTSENS measurements of Y were repeatable over continuous cardiac cycles for all the recruited subjects (beat-to-beat variation < 6 %). The mean of Y measured for all the subjects was $262.8pm 99$ kPa. The accuracy of the system was evaluated by a comparative analysis against a reference B-mode imaging modality. Regression analysis of the data showed that the Y measurements that were taken by ARTSENS significantly correlated (r = 0.90, p < 0.001) to the reference system measurements. Bland Altman analysis indicated a strong degree of agreement between measurements taken by the two devices, with an insignificant difference (p = 0.32).
机译:动脉的杨氏模量(Y)是量化的材料刚度的动脉的一个重要的弹性特性。一些研究表明,Y和标准偏差的定量值可以潜在地用于冠状动脉心脏疾病的独立预测因子。用于Y的可靠测量,需要动脉直径和壁厚的精确的测量。传统地,这些动脉尺寸由成像中不进行大规模筛选的可行选择系统由于它们的形状因数和高复杂度的测量。在这项工作中,我们提出了一种便携式免图像超声模态 - ARTSENS笔为Y. ARTSENS的测量是一个广泛验证技术能够提供动脉的尺寸和刚度的临床标准测量。在目前这个工作,我们已经证明了ARTSENS的能力,使的装置Y的性能精确和可重复的测量是通过体内研究证实在15个科目。 Y的ARTSENS测量是可重复的上方对所有的受试者招募连续的心动周期(节拍到搏动变化<6 %)。所有受试者中测得的平均的Y为262.8 $ 下午99 $千帕。该系统的准确度是由与参考B模式成像模态进行比较分析进行评价。数据的回归分析发现,采取由ARTSENS的Y测量显著相关(r = 0.90,P <0.001)与基准系统测量。布兰德Altman分析指示由两个设备拍摄,与非显着性差异(p = 0.32)的测量之间的协议强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号