In engineering practice, the status evaluation of isolating switches is often carried out, and intelligent operation and maintenance are carried out based on the results of the status evaluation. It is necessary to master the basic information such as the defect rate and main defect modes of isolating switches. Based on the statistics of the isolation switches, the isolating switches are classified according to the structure, and the quantity and defect rate of different types of isolation switch under the voltage level of 110kV, 220kV and 500kV are calculated respectively. Then the parts of the isolation switch are divided, the types and proportions of defects in each part of the isolation switch are counted, and the defect information of the isolation switch is summarized from various aspects. Finally, it is found that although the defect rate of the isolating switches will be different due to different structures and voltage levels, the mechanism box is always the component with the largest defect proportion of the isolating switches, and the defect modes are diverse. The defect proportion of other components is relatively low and the defect type is relatively single.
机译:在工程实践中,通常进行隔离开关的状态评估,并根据状态评估结果进行智能操作和维护。有必要掌握隔离交换机的缺陷率和主要缺陷模式等基本信息。基于隔离开关的统计,分别根据该结构对隔离开关进行分类,并分别计算在110kV,220kV和500kV的电压电平下的不同类型隔离开关的数量和缺陷率。然后,分开隔离开关的部分,计数隔离开关的每个部分中的缺陷的类型和比例,并且总结了隔离开关的缺陷信息。最后,发现虽然隔离开关的缺陷率由于不同的结构和电压电平而不同,但是机构箱总是具有最大缺陷比例的分离开关的组件,并且缺陷模式是多样的。其他组件的缺陷比例相对较低,缺陷类型相对单。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号