MEASURING WATER FILM THICKNESS IN A WET GAS COMPRESSOR DIFFUSER - DESIGN, CALIBRATION, AND TESTING OF ELECTROMAGNETIC PROBES

机译:测量湿气压缩机扩散器中水膜的厚度-电磁问题的设计,校准和测试

获取原文

摘要

The distribution of water in the diffuser of a wet gas compressor is not well understood. Measurements of water film thickness across the diffuser surface would improve the understanding of two-phase flow phenomena in wet gas compressors. Electromagnetic probes were designed in order to measure water film thickness in the diffuser of a SwRI-designed wet gas compressor. The probes consisted of two electrode foils plated on a thin insulating substrate, allowing them to be bonded in place without drilling through the diffuser. An AC signal was passed between the electrodes, and the voltage across a resistor in series with the electrodes was recorded. As the water level covering the electrodes increased, the recorded voltage increased. A method of calibrating the probes was developed and used prior to installation in the diffuser. Testing showed the probes to be effective at detecting the presence of water in the diffuser and indicating the general water level. Improvements in probe design, calibration, and installation are needed to provide more precise water film thickness data.
机译:水在湿式气体压缩机的扩散器中的分布不是很清楚。横跨扩散器表面的水膜厚度的测量将改善对湿气压缩机中两相流动现象的理解。设计电磁探针是为了测量SwRI设计的湿式气体压缩机的扩压器中的水膜厚度。探针由镀在薄绝缘基板上的两个电极箔组成,使它们可以结合在一起就位,而无需钻穿扩散器。 AC信号在电极之间通过,并记录与电极串联的电阻两端的电压。随着覆盖电极的水位增加,记录的电压增加。在安装到扩散器中之前,开发并使用了一种校准探针的方法。测试表明,该探头可有效检测扩散器中是否存在水,并指示总体水位。需要改进探头的设计,校准和安装,以提供更精确的水膜厚度数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号