摘要

This paper presents a study of the influence of the positive sequence voltage on the derating of three-phase induction motors under voltage unbalance and its comparison with the NEMA derating curve. Three criteria for derating induction motors under unbalanced voltages are presented: the rated current, the rated equivalent current and the rated losses. These criteria are theoretical and experimentally analyzed. A 4 kW three-phase induction motor was used in the study. The paper suggests that the positive sequence voltage must be considered together with the Voltage Unbalance Factor VUF (or Percent Voltage Unbalance PVU) index for derating purposes. If only the VUF (or PVU) index is taken into account, a facility user cannot appropriately derate the motor.
机译:本文研究了正序电压对三相异步电动机在电压不平衡下降额的影响及其与NEMA降额曲线的比较。提出了不平衡电压下感应电动机降额的三个标准:额定电流,额定等效电流和额定损耗。这些标准是理论上和实验上分析的。研究中使用了4 kW三相感应电动机。本文建议,为了降额,必须将正序电压与电压不平衡因数VUF(或电压不平衡百分数PVU)指数一起考虑。如果仅考虑VUF(或PVU)指数,设施用户将无法适当降低电动机的额定功率。