Special reprocessing logic for contingency analysis with special protection systems

机译:特殊的后处理逻辑,用于通过特殊保护系统进行的意外事件分析

获取原文

摘要

Power grids across the world have specific areas in their power systems that have a weak transmission network. Loss of certain critical transmission elements in these areas becomes a major concern for operations in the EMS Control Centers. Analysis of such contingent events is complex as these contingencies force the solution to go beyond the knee of the P-V curve, which causes the contingency to go unsolved. This paper describes an approach for reprocessing logic in the Contingency Analysis (CA) engine to help solve those contingencies that are beyond the knee of the P-V curve in order to assess system impacts and related Special Protection Schemes (SPS). This approach has been implemented recently into Real-Time Contingency Analysis application (RTCA) of EMS system at ISO-New England and it provides a way to analyze SPS actions under stressed system conditions.
机译:全世界的电网在其电力系统中都有传输网络薄弱的特定区域。这些区域中某些关键传输元件的丢失已成为EMS控制中心运营中的主要问题。对这些或有事件的分析非常复杂,因为这些或有事件迫使解决方案超出了P-V曲线的拐点,这导致了或有事件无法解决。本文介绍了一种在应急分析(CA)引擎中进行逻辑再处理的方法,以帮助解决那些超出P-V曲线拐点的突发事件,以便评估系统影响和相关的特殊保护方案(SPS)。这种方法最近已在新英格兰ISO的EMS系统的实时应变分析应用程序(RTCA)中实施,它提供了一种在压力系统条件下分析SPS行为的方法。