Methodology to analyze failure mechanisms of ohmic contacts on MEMS switches

机译:分析MEMS开关上欧姆接触的故障机理的方法

获取原文

摘要

This paper demonstrates the efficiency of a new methodology using a commercial nanoindenter coupling with electrical measurement on test vehicles specially designed to investigate the micro contact reliability. This study examines the response of gold contacts with 5 mum2 square bumps under various levels of current flowing through contact asperities. Contact temperature rising is observed leading to shifts of the mechanical properties of contact material, modifications of the contact topology and a diminution of the time dependence creep effect. The data provides a better understanding of micro-scale contact physics especially failure mechanisms due to the heating of the contact on MEMS switches.
机译:本文演示了一种新方法的效率,该方法在专门设计用于研究微接触可靠性的测试车辆上使用商业纳米压头与电测量相结合。这项研究研究了5mm 2 方形凸点的金触点在各种水平的电流通过触点粗糙时的响应。观察到接触温度升高导致接触材料的机械性能发生变化,接触拓扑的变化以及与时间相关的蠕变效应的减小。数据可以更好地理解微型接触物理,尤其是由于MEMS开关上的接触发热而引起的故障机理。