首页> 外文会议>Energy and Environment Technology, 2009. ICEET '09 >Experimental Research of the Falling-Film Evaporation Characteristic outside Horizontal Heat Pipe in the Vacuum
【24h】

Experimental Research of the Falling-Film Evaporation Characteristic outside Horizontal Heat Pipe in the Vacuum

机译:真空中水平热管外降膜蒸发特性的实验研究

获取原文

摘要

Face the energy crisis in the world, it is important to improve the utilization efficiency of the energy conversion. The evaporation characteristic of the falling film outside heat pipe in the vacuum as a good evaporation method was studied in the paper. The negative pressure falling film evaporation on the horizontal heat pipe experiment set was constructed. The impacts of the spray water load, spray water temperature, the wall temperature of the heat pipe, the vacuum on the falling-film evaporation were analyzed on the base of the experiment. Results of this study showed that the vacuum was favorable for improving evaporation efficiency. It could be used in the electric power, chemical plant and etc. fields to save energy.
机译:面对世界上的能源危机,提高能量转换的利用效率非常重要。本文研究了真空下降膜在热管中的蒸发特性,以此作为一种良好的蒸发方法。构造了水平热管实验装置上的负压降膜蒸发。在实验的基础上,分析了喷水量,喷水温度,热管壁温,真空度对降膜蒸发的影响。研究结果表明,真空有利于提高蒸发效率。可用于电力,化工厂等领域,以节约能源。