摘要

The authors carried out a study of the effect of organic materials on contact resistance, taking as a typical contamination source paraffin hydrocarbons, which are the most general kind of contact contaminant and are used in the various machines in the manufacturing processes, to clarify the problem of contact reliability caused by contamination by organic materials during the manufacturing process. In addition, the authors also studied conventional methods of contact cleaning as well as cleaning methods that could conceivably be used instead of conventional methods. As a result of this study, it was found that, even when the thickness of organic membranes was around 100 AA, the contact resistance increased along with the passage of time. This trend was particularly prominent at the normally open contact side. The authors also found that alternate methods of removing these organic films, such as CO/sub 2/-laser cleaning, were quite effective.
机译:作者对有机材料对接触电阻的影响进行了研究,以石蜡烃作为一种典型的污染源,这是最常见的接触污染物,在制造过程中的各种机器中都使用过,以阐明问题所在。制造过程中由有机材料污染引起的接触可靠性的评估。另外,作者还研究了常规的接触清洁方法以及可以想到的替代常规方法的清洁方法。作为该研究的结果,发现即使有机膜的厚度为约100AA,接触电阻也随着时间的流逝而增加。这种趋势在常开触点侧尤为突出。作者还发现,去除这些有机膜的替代方法(例如CO / sub 2 /激光清洁)非常有效。