OPC UA Communication Traffic Control for Analogue Values in an Automation Device with Embedded OPC UA Servers

机译:具有嵌入式OPC UA服务器的自动化设备中用于模拟值的OPC UA通信流量控制

获取原文

摘要

Modern distributed industrial control systems needs to transfer many different types and amounts of information between different devices. One type of information is measurements - analogue information directly from the production level. In order to achieve the technological requirements of a production system, an open standard Open Process Control - Unified Architecture (OPC UA) system was selected. An embedded automation device equipped with an OPC UA server can either transmit deadband tested analogue attributes or all of the changes of the analogue attributes to the OPC UA clients. The subscription interval, sampling interval and deadband are controlled by the OPC UA clients. While the floating point attributes in an automation device change all the time, in real industry systems, the analogue attributes of small changes do not necessarily have to be communicated to the OPC UA clients frequently. In addition to the attribute deadband test, changes in some of the attributes can safely be blocked for a minimum amount of time after the last attribute update before a new value is transmitted to the UA clients. Due to the nature of deadbands in attribute communication, analogue attributes should also be transmitted to the OPC UA clients at a low frequency to make sure that the client receives the correct attribute value after a set maximum time. This paper shows an approach to OPC UA data traffic control using a Programmable Logic Controller (PLC) function block to control traffic of analogue attributes a server and its clients.
机译:现代分布式工业控制系统需要在不同设备之间传输许多不同类型和数量的信息。信息的一种类型是测量-直接来自生产级别的模拟信息。为了满足生产系统的技术要求,选择了开放标准的开放过程控制-统一体系结构(OPC UA)系统。配备有OPC UA服务器的嵌入式自动化设备可以将经过死区测试的模拟属性或模拟属性的所有更改传输到OPC UA客户端。订阅间隔,采样间隔和死区由OPC UA客户端控制。尽管自动化设备中的浮点属性一直在变化,但是在实际工业系统中,小变化的模拟属性不一定必须频繁地传达给OPC UA客户端。除了属性死区测试之外,在最后一个属性更新之后,在将新值传输到UA客户端之前,可以安全地在最短时间内阻止某些属性的更改。由于属性通信中死区的性质,模拟属性也应以较低的频率传输到OPC UA客户端,以确保客户端在设置的最大时间后收到正确的属性值。本文展示了一种使用可编程逻辑控制器(PLC)功能块来控制服务器及其客户端的模拟属性流量的OPC UA数据流量控制方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号