首页> 外文会议>European symposium on computer aided process engineering >Numerical Analysis of Radiant Section of Fired Heater Focused on the Effect of Wall-Tube Distance
【24h】

Numerical Analysis of Radiant Section of Fired Heater Focused on the Effect of Wall-Tube Distance

机译:壁式炉管距离影响的火焰加热器辐射截面数值分析

获取原文

摘要

Vertical cylindrical fired heater as used in crude oil atmospheric distillation unit is simulated numerically to analyse the distribution of thermal loading on the tubes. The model describes flow, gas combustion and radiative heat transfer inside the radiation section of the fired heater. Attention is focused on the tube-wall distance and the effect it has on circumferential distribution of heat flux on tube walls. It is shown that assumptions invoked in ID design calculations of fired heaters are significantly underestimating heat flux variability.
机译:对原油常压蒸馏装置中使用的立式圆柱燃烧加热器进行了数值模拟,以分析管子上的热负荷分布。该模型描述了燃烧加热器辐射部分内部的流动,气体燃烧和辐射热传递。注意集中在管壁距离及其对管壁上热通量的周向分布的影响上。结果表明,在燃烧加热器的内径设计计算中引用的假设大大低估了热通量的可变性。