The paper discusses a control system of a three-phase step-up converter which in addition to control functions performs phase current correction. Study of the control system operation is carried out and expressions for calculating the maximum permissible values of error amplifier factors are obtained. Influence of the error amplifier parameters on phase current quality is investigated. At a given value of power factor the dependence of total harmonic distortion as per IEC 61000-3-12:2004 on a combination of error amplifier parameters is obtained. The conditions under which the total harmonic distortion has a minimum value are found out. This article is of interest to power electronics engineers, who aim to develop three-phase AC-to-DC converters with input phase currents of high quality.
机译:本文讨论了三相升压转换器的控制系统,除了控制功能之外,还执行相电流校正。 对控制系统操作进行研究,获得了计算用于计算误差放大器因子的最大允许值的表达式。 研究了误差放大器参数对相电流质量的影响。 在给定值的功率因数值,获得根据IEC 61000-3-12:2004在误差放大器参数的组合上的总谐波失真的依赖性。 发现总谐波失真具有最小值的条件。 本文对电力电子工程师感兴趣,该工程师旨在开发三相AC-TO-DC转换器,具有高质量的输入相电流。