The ideal focal curve for the soft x-ray flat-field spectrometer is a straight line, but the real one is not, thus the inconformity of aberrations between different wavelengths in the working waveband is inevitable. In order to further reduce aberrations and improve spectral resolutions, multi-area gratings (divided perpendicular the direction of grating grooves) are devised. Firstly, the grating is divided into three areas, and the spectral aberrations for these areas are analyzed by means of ray tracing. Then, diffraction efficiencies for the areas with worse aberrations should be reduced to lower the proportion regional aberrations contributing to the overall aberration, therefore better spectral image could be obtained and the spectral resolution would be improved. Theoretical analysis demonstrates that: using multi-area grating, the spectral resolutions at wavelength of 0.8 and 1.1 nm are increased from 123 and 333 to 401 and 671, respectively. At the same time, the spectral resolutions at other wavelengths are not reduced.
机译:软X射线平场光谱仪的理想聚焦曲线是一条直线,但不是真正的直线,因此,在工作波段中不同波长之间像差的不一致性是不可避免的。为了进一步减小像差并提高光谱分辨率,设计了多区域光栅(垂直于光栅凹槽的方向划分)。首先,将光栅分为三个区域,并通过光线追踪分析这些区域的光谱像差。然后,应降低像差较差区域的衍射效率,以降低占总像差的区域像差的比例,因此可以获得更好的光谱图像,并且可以提高光谱分辨率。理论分析表明:使用多区域光栅,波长为0.8和1.1 nm时的光谱分辨率分别从123和333增加到401和671。同时,其他波长的光谱分辨率不会降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号