首页> 外文会议>Audio Engineering Society international conference >POTENTIAL ERRORS OF REAL-EAR-TO-COUPLER-DIFFERENCE METHOD APPLIED FOR A PREDICTION OF HEARING AID PERFORMANCE IN AN INDIVIDUAL EAR
【24h】

POTENTIAL ERRORS OF REAL-EAR-TO-COUPLER-DIFFERENCE METHOD APPLIED FOR A PREDICTION OF HEARING AID PERFORMANCE IN AN INDIVIDUAL EAR

机译:实耳耦合误差方法的潜在误差在个体耳中助听器性能预测中的应用

获取原文

摘要

The sound pressure that a hearing aid or an insert earphone generates in an individual ear will depend on the impedance of an individual ear and will vary from person to person. Therefore it is important to calibrate a hearing aid for an individual ear in order to obtain a correct prescribed gain. Real Ear to Coupler Difference (RECD) is a measure that allows to predict the sound pressure that a hearing aid or an insert earphone will create in an occluded ear based on the results of the sound pressure measured in a 2-cc test coupler. The purpose of this article is to analyze the potential errors of the sound pressure in an occluded ear estimated via RECD.
机译:助听器或插入式耳机在单个耳朵中产生的声压将取决于单个耳朵的阻抗,并且会因人而异。因此,重要的是校准单个耳朵的助听器以获得正确的规定增益。实际耳耦合器差异(RECD)是一种度量,它可以根据在2 cc测试耦合器中测得的声压结果,预测助听器或插入式耳机会在闭塞的耳朵中产生的声压。本文的目的是分析通过RECD估计的被闭塞的耳朵中声压的潜在误差。