The degradation of insulation materials of the multi-contacts electrical connector often resulted in malfunction of the electronic system in harsh environment, due to which, we put up a model for the electrical connector with degraded insulation and the simulation for the model was also investigated. It was found that a current leakage channel was formed because of the degradation of the insulation which reduced the resistance of the insulation materials markedly. Through the channel the signals between the two contacts affected each other, the result of which was that the signals turned to be the mixed one of the signals in different contacts, and as the resistance of the insulation materials reduced, the signal is distorted badly and badly.
机译:多触点电连接器绝缘材料的劣化通常会导致恶劣环境中电子系统的故障,因此,我们建立了绝缘性能下降的电连接器模型,并对该模型进行了仿真。已经发现,由于绝缘的劣化而形成了电流泄漏通道,从而显着降低了绝缘材料的电阻。通过该通道,两个触点之间的信号相互影响,其结果是该信号变成了不同触点中信号的混合之一,并且随着绝缘材料电阻的减小,该信号严重失真,并且不好