Results of a recently developed refined, high-sensitive electrical resistance (ER)measurement method for corrosion monitoring are presented. Steel probes plated withsemi-bright zinc coatings without passivation, with blue chromate, blue chromate andsilicate-based sealer and with yellow chromate were tested by the ER method incombination with cyclic corrosion test (CCT) in a salt spray chamber. The ER method isshown to provide fast quantitative corrosion measurements in chamber tests. In mostcases an instant corrosion rate can be calculated after a few hours exposure in CCT,whereas visual inspections will require exposure for several days to reveal corrosion.To test the reliability of the ER-measurements as compared to well-known methods,additional corrosion experiments on zinc-plated steel immersed in NaCl-solution wereperformed. Results from electrochemical impedance spectroscopy (EIS), weight-lossmeasurements and ER-measurements were in quite good agreement, confirming thereliability of the new ER-method.
机译:最近开发的改进的高灵敏电阻(ER)的结果 介绍了腐蚀监测的测量方法。钢探针镀有 半光亮锌涂层,无钝化,具有蓝色铬酸盐,蓝色铬酸盐和 硅酸盐基密封剂和黄色铬酸盐通过ER方法在 与盐雾室内的循环腐蚀测试(CCT)相结合。 ER方法是 显示可以在腔室测试中提供快速的定量腐蚀测量。多数情况 在CCT中暴露几个小时后可以计算出即时腐蚀率的情况, 而目视检查将需要暴露几天才能发现腐蚀。 为了测试ER测量与已知方法相比的可靠性, 还对浸入NaCl溶液中的镀锌钢进行了另外的腐蚀实验 执行。电化学阻抗谱(EIS)的结果,重量减轻 测量值和ER测量值非常吻合,证实了 新的ER方法的可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号