Unique relationship between interfacial tension test (IFT) and neutral number test (Acidity) of transformer insulation oil in PLN P3B JB-Jakarta and Banten Regional

机译:PLN P3B JAKARTA和BANTEN区域界面张力试验(IFT)和中性数量试验(IFT)和中性数量试验(酸度)的独特关系

获取原文

摘要

Transformers are one of some important equipment on electricity network. Each utility, in this case PLN P3B Jawa-Bali, has to assure their reliability in order to maintain electrical power system stability by assessing transformer conditions. Insulation system, which consists of liquid and solid insulation, is the most important part of transformer system. The performance of transformer will depend on its insulation system. Solid insulation has a function to provide mechanical strength, dielectric strength and dielectric spacing. Liquid insulation has a function to provide dielectric strength, cooling and protect the active material. To assess the quality of liquid insulation in this term is insulation oil there are several test that can be done i.e. water content, breakdown voltage, acidity, interfacial test, sediment, flash point and color. These tests will give information whether the insulation is in normal ageing condition or in accelerating ageing condition due to oxidation. This paper will explain the typical of Interfacial tension test (IFT), neutral number test (acidity) during degradation process due to oxidation in PLN P3B JB – Jakarta and Banten regional and the unique relationship between interfacial tension test and neutral number test (acidity) itself. The data shown that an increasing of neutral number (acidity) value always followed by a characteristic drop in IFT. Our analysis that we’ve done refer to oil quality test in PLN P3B JB Jakarta & Banten regional at 2008 which consist of 250 transformers.
机译:变压器是电力网络上的一些重要的设备之一。每个实用程序,在这种情况下PLN P3B爪哇-巴利,必须保证,以便通过评估变压器的条件以维持电力系统的稳定性的可靠性。绝缘系统,它由液体和固体绝缘的,是变压器系统的最重要的部分。变压器的性能将取决于其绝缘系统。固体绝缘具有如下功能,以提供机械强度,介电强度和介电间隔。液体绝缘具有如下功能:提供介电强度,冷却和保护活性材料。为了评估液体绝缘的质量在该术语是绝缘油有若干测试,可以做即水含量,击穿电压,酸度,界面测试,沉积物,闪点和颜色。绝缘是否处于正常老化条件下或在加速老化条件下,由于氧化这些测试将提供信息。本文将解释典型的过程中降解过程界面张力测试(IFT),中性数试验(酸度)的由于在PLN P3B JB氧化 - 雅加达和万丹区域和界面张力测试和中性数试验(酸度)之间的独特关系本身。所示的数据,一个中性数目的增加(酸度)的值总是跟随在IFT的特性下降。我们的分析,我们已经做了参考油的质量测试,PLN P3B JB雅加达及万丹地区于2008年,其包括250个变压器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号