首页> 外文会议> >Design Of Microcalorimeters For Evaluation Of PropellantsIn Medium Caliber Munitions
【24h】

Design Of Microcalorimeters For Evaluation Of PropellantsIn Medium Caliber Munitions

机译:中口径弹药发射药量热计的设计。

获取原文

摘要

Conventional commercial microcalorimeters are limited in size. Studies of propellants removedfrom munitions are limited to 4- gram sizes. These small sizes do not correctly represent the heatflow that result by the original environment of the hardware configuration. Large calorimetermeasuring cells have been designed by ESB that use inexpensive Hart Scientific commercialprecision water baths. The sensitivity of the measuring cell is a maximum of +/- 0.5 microwatt orbetter operating from 40°C to 80°C with propellant samples from 4-grams to 100-grams. Thecalorimeter cells have been tested with 20-mm and 25-mm cartridges as received from service use.Unique cell designs and factors that affect performance of the calorimeter-measuring cell arediscussed. Validation data is presented showing how the munition round compares with smallpropellant samples removed from rounds. The calorimeter heat flow data is collected with a lowcost high-resolution data collection system.
机译:常规的商业量热仪的尺寸受到限制。推进剂研究被删除 弹药不得超过4克大小。这些小尺寸不能正确代表热量 硬件配置的原始环境产生的流量。大热量计 ESB已设计出可使用廉价Hart Scientific商业产品的测量池 精密水浴。测量池的灵敏度最大为+/- 0.5微瓦或 推进剂样品从4克到100克,可在40°C至80°C的温度下更好地工作。这 量热仪电池已在使用时从20毫米和25毫米滤芯中进行了测试。 独特的电池设计和影响热量计测量电池性能的因素是 讨论过。验证数据显示了弹药与小型弹药的比较 从炮弹中取出推进剂样品。量热仪的热流数据收集低 成本高的高分辨率数据收集系统。