首页> 外文会议> >Successful high power test of a proton linac booster (LIBO) prototype for hadrontherapy
【24h】

Successful high power test of a proton linac booster (LIBO) prototype for hadrontherapy

机译:用于强子疗法的质子直线加速器(LIBO)原型的成功高功率测试

获取原文

摘要

The linac booster (LIBO) project aims to build a 3 GHz proton linac to give the beam from 50-70 MeV cyclotrons, which exist in several laboratories and hospitals, a final energy of 200 MeV. This will allow the treatment of deep-seated tumours. A prototype of the first LIBO module was designed, constructed and RF tested by a collaboration of CERN, University and INFN of Milan, University and INFN of Naples, and the TERA Foundation. Low power RF measurements have shown good field uniformity and stability along the axis of the four tanks composing the LIBO module. In December 2000, full power RF measurements at a repetition rate of 100 Hz have been performed at CERN. After a very short conditioning period, an accelerating gradient approaching 30 MV/m has been easily achieved in the tanks, well above the nominal 15.8 MV/m. The particularities of the design and the reasons for the successful performance are discussed.
机译:直线加速器助力器(LIBO)项目旨在制造3 GHz质子直线加速器,以提供来自50-70 MeV回旋加速器的束,该回旋加速器存在于多个实验室和医院中,最终能量为200 MeV。这将允许治疗深部肿瘤。第一个LIBO模块的原型是由CERN,米兰大学和INFN,那不勒斯大学和INFN以及TERA基金会合作设计,建造的,并进行了射频测试。低功率RF测量显示沿组成LIBO模块的四个储罐的轴具有良好的场均匀性和稳定性。 2000年12月,欧洲核子研究组织(CERN)以100 Hz的重复频率进行了全功率RF测量。经过很短的调节期后,在储罐中很容易达到了接近30 MV / m的加速梯度,远高于标称值15.8 MV / m。讨论了设计的特殊性和成功执行的原因。