首页> 外文会议> >A method for the monitoring of the air-pollution in the operating room caused by anaesthesia agents
【24h】

A method for the monitoring of the air-pollution in the operating room caused by anaesthesia agents

机译:一种监测麻醉剂引起的手术室空气污染的方法

获取原文

摘要

Volatile anaesthetic agents polluting the operating theatre atmosphere constitute a major chemical hazard source. A gas chromatographic method using a frequency modulated ECD and a mass spectrometer (1-200 AMU) have been used for the determination of nitrous oxide, halothan and isofluoran traces in operating theatre atmosphere. The sampling devices includes a small movable rotary pump, which inflates nylon bags, 60 ml grease-free syringes and balloons. Since no standards are commercially available, a static calibration method employing a 25 l gas extricator into which liquid halothane or isofluorane is introduced, by using a micropippete and isothermally vaporised and a dynamic method employing N/sub 2/O, N/sub 2/, O/sub 2/ gas cylinders equipped with flow-meters allowing the formation of variable partial pressure mixtures have been developed. The sensitivity of the method is /spl ap/1 ppm (v/v) for halothane and isofluorane and /spl ap/10 ppm (v/v) for nitrous oxide.
机译:挥发性麻醉剂污染手术室的气氛是主要的化学危险源。使用调频ECD和质谱仪(1-200 AMU)的气相色谱法已用于确定手术室气氛中的一氧化二氮,卤代烷和异氟烷痕量。采样设备包括一个小型可移动旋转泵,可为尼龙袋,60毫升无油脂注射器和气球充气。由于没有标准品可供使用,因此采用微量离心管并通过等温汽化的方法,使用25 l气体抽提机(其中引入了液体氟烷或异氟烷)的静态校准方法,以及使用N / sub 2 / O,N / sub 2 /的动态方法。 ,已开发出配备有流量计的O / sub 2 /气瓶,该流量计允许形成可变的分压混合物。该方法的灵敏度对于氟烷和异氟烷为/ spl ap / 1 ppm(v / v),对于一氧化二氮为/ spl ap / 10 ppm(v / v)。