首页> 外文会议> >Electromagnetic compatibility for communications based signaling systems
【24h】

Electromagnetic compatibility for communications based signaling systems

机译:基于通信的信号系统的电磁兼容性

获取原文

摘要

The results of an investigation which occurred at the Docklands Light Railway, London, UK, in the fall of 1994 are presented. Alcatel's SELTRAC system was being installed and commissioned on an operating railway. The existing signaling system for the railway had been installed by General Electric Corporation, Alsthom Signaling Limited (GASL) of the United Kingdom. Both systems are transmission based, and used a cable laid down the center of the guideway for communications with vehicles. Problems were noted at various points of the guideway, and an investigation conducted to determine the source of the problems, and to implement corrective actions. The investigation first focused on external interference, then turned to interference between the two signaling systems, the complex interaction of the systems, the ironwork of the guideway, and the ballast resistance of the track. The steps of the investigation are presented, along with the results, the coupling mechanism which was ultimately responsible, and the corrective actions which were successfully implemented.
机译:提出了在1994年南部驻地驻码伦敦伦敦伦敦电铁路的调查结果。阿尔卡特的Seltrac系统正在运营铁路上安装和委托。铁路现有的信号系统已由英国Alsthom Signaling Limited(Gasl)一般电气公司安装。两个系统都是基于透射的,并使用电缆放下导轨的中心以进行与车辆通信。在导轨的各个点上注意到问题,并进行了调查以确定问题的来源,并实施纠正措施。调查首先专注于外部干扰,然后转向两种信号系统之间的干扰,系统的复杂相互作用,导轨的熨斗和轨道的镇流阻力。调查的步骤以及结果,耦合机制最终归于负责,以及成功实施的纠正措施。