On-line insulation monitoring of heavy duty coal face electrical drives using zero sequence current harmonics

机译:使用零序电流谐波在线监测重型采煤工作面电力驱动装置

获取原文

摘要

One of the major drawbacks of a restricted-neutral system of electrical power supply used in underground coal mines of many countries is the lack of on-line insulation monitoring facility and early warning capability during deterioration of system insulation level. The paper outlines a novel technique of noninvasive on-line insulation monitoring for a restricted neutral system of power supply using harmonics content of zero sequence current reflected in the secondary winding of a core balance transformer.
机译:许多国家地下煤矿中使用的限制 - 中立系统的主要缺点之一是在系统绝缘水平的恶化过程中缺乏在线绝缘监测设备和早期预警功能。本文概述了使用核心平衡变压器的次级绕组中的谐波含量的谐波含量的谐波含量的限制中性电源的非侵入式中性系统的新技术。