The dielectric performance of gas-insulated switchgear (GIS) is critical to its long term service integrity. Many parameters that are of little significance to open type air insulated switchgear are of vital importance to GIS. Detailed on-site examination is necessary to ensure chamber cleanliness during site erection as a foreign object left inside can in itself induce dielectric breakdown. In addition loose, or ineffectively bonded, line or earth side components can vibrate under the effects of both magnetic and electrostatic forces to induce partial discharge activity.
机译:气体绝缘开关设备(GIS)的介电性能对其长期服务的完整性至关重要。对于开放式空气绝缘开关设备而言,许多参数意义不大,这对GIS至关重要。必须进行详细的现场检查,以确保在现场安装过程中保持腔室清洁,因为内部残留的异物本身会引起绝缘击穿。另外,松散的或无效粘合的线路或接地组件可能会在电磁力和静电力的作用下发生振动,从而引起局部放电活动。