摘要

A novel DC method for determining the components of series resistance in bipolar transistors is presented. As a DC technique, it shows unprecedented accuracy as demonstrated by its application to both metal-contacted heterojunction transistors and more conventional bipolar junction transistors. The measurement error was minimized by using a single double-base Kelvin-tapped transistor to extract all components of series resistance. The present work indicates that past methods for calculating the bias dependence of series resistances in bipolar devices are incorrect. Therefore, a correct expression for the bias-dependent intrinsic base resistance is also presented.
机译:提出了一种新颖的直流方法来确定双极型晶体管中串联电阻的成分。作为直流技术,它在金属接触异质结晶体管和更常规的双极结晶体管中的应用证明了其前所未有的准确性。通过使用单个双基极开尔文抽头晶体管提取串联电阻的所有分量,可将测量误差降至最低。当前的工作表明,过去用于计算双极型器件中串联电阻的偏置相关性的方法是不正确的。因此,还给出了与偏置相关的固有基极电阻的正确表达。