This study experimented on a heating and cooling system that uses thedeep ocean water as a heat source in a laboratory equipped with thewater intake system. Experiments on direct cooling using the deepocean water of yearlong temperatures at 5℃ or less were performed.Experiments on heating using a heat pump system were performed withvarious ocean waters as heat sources including the deep ocean water at5℃, the surface ocean water at 10oC, and the ground ocean water at13℃, among others. The comparison results between the conventionalcooling systems and the direct cooling system using the deep oceanwater revealed that the latter saved approximately 82.7% of the totalpower consumption and reduced the carbon dioxide exhaust by about75.6 kgCO_2. The heating COPs of the surface ocean water and theground ocean water increased by approximately 21.2% and 28.4%more, respectively, than that of the deep ocean water.
机译:这项研究在配备有进水系统的实验室中使用深海水作为热源的加热和冷却系统进行了实验。进行了使用温度在5℃或以下的一年的深海水直接冷却的实验。使用热泵系统进行加热实验,以各种海水为热源,包括5℃的深层海水,10oC的地表海水,以及13℃的地下水。常规冷却系统与使用深海水的直接冷却系统的比较结果表明,后者可节省总能耗的约82.7%,并减少二氧化碳排放约75.6 kgCO_2。与深海水相比,地表海水和地上海水的加热COP分别增加了约21.2%和28.4%。