Analysis on the Performance of Ground Heat Exchangers in Ground Source Heat Pump Systems Based on Heat Transfer Enhancements

机译:基于传热增强的地源热泵系统地热交换器性能分析

获取原文

摘要

The heat transfer performance of a ground heat exchanger (GHE) is the key factor in practical operation of a ground source heat pump (GSHP) system. Based on calculation and analysis thermal resistance of vertical GHE, this paper have analyzed main factors, which influence the heat transfer performance of ground heat exchangers’ (GHEs) under different conditions. Combining practical engineering application, approaches of reducing the thermal resistance and enhancing heat transfer of GHE are proposed. For improving heat transfer efficiency and reducing unnecessary heat waste, a new ground heat exchanger with three inlet pipes and one outlet pipe (“3-in&1-out”) is introduced. And according to the results of theoretical calcula-tion and analysis, it is revealed that the heat transfer resistances of the GHE with “3-in&1-out” pipes under variable conditions are always less than that of GHEs with either single U-pipe or double U-pipe. Thus the performance of the GHE with “3-in&1-out” pipes is worthy of further analysis.
机译:地面热交换器(GHE)的传热性能是地面源热泵(GSHP)系统实际操作中的关键因素。在对立式换热器的热阻进行计算分析的基础上,分析了影响地面换热器在不同条件下传热性能的主要因素。结合实际工程应用,提出了降低GHE热阻和提高热传递的方法。为了提高传热效率并减少不必要的热量浪费,引入了一种新的地面热交换器,该热交换器具有三个入口管和一个出口管(“ 3-in&1-out”)。并且根据理论计算和分析的结果表明,“三进一出”管在可变条件下的GHE的传热阻力始终小于单U管或单U管的GHE的传热阻力。双U型管。因此,带有“三进一出”管道的GHE的性能值得进一步分析。