Limit Operating Frequency of Peak Current-Mode Control DC-DC Converter Considering Turn-Off Delay Time

机译:考虑关断延迟时间的峰值电流模式控制DC-DC转换器的极限工作频率

获取原文

摘要

The aim of this paper is to present the mechanism of the frequency dividing operation and the limit operating frequency in the peak current-mode control DC-DC converter considering the turn-off delay time. The peak current mode control has the higher stability and the responsiveness than the conventional voltage mode control. However, if the switching frequency is increased ignoring the turn-off delay time, it would become the frequency dividing operation that the switching frequency operates lower than the clock frequency at the certain frequency. In this operation, there is a problem that the switching loss increases and the high frequency switching drive is hindered. In this paper, we clarified the mechanism of the dividing frequency operation and derived the relationship between the turn-off delay time and the limit operating frequency. Also, we derived the relationship when the slope compensation is applied as well. As experimental results, when there is the turn-off delay time, it was confirmed that the limit operating frequency of the DC-DC converter was limited to lower as the duty ratio was lower and the slope ratio of the slope compensation is close to 1.0.
机译:本文的目的是提出考虑关断延迟时间的峰值电流模式控制DC-DC转换器中的分频操作和极限工作频率的机制。峰值电流模式控制具有比常规电压模式控制更高的稳定性和响应性。但是,如果忽略关断延迟时间而增加开关频率,则开关频率在一定频率下的工作频率低于时钟频率将成为分频操作。在该操作中,存在开关损耗增加并且阻碍了高频开关驱动的问题。在本文中,我们阐明了分频操作的机理,并得出了关断延迟时间与极限工作频率之间的关系。此外,我们还推导了在应用斜率补偿时的关系。作为实验结果,在存在断开延迟时间的情况下,可以确认占空比较低,斜率补偿的斜率接近1.0时,DC-DC转换器的极限工作频率被限制得较低。 。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号