首页> 外文会议>International conference on structural engineering, mechanics and computation >Experimental response of S2-glass fibre reinforced composites subjected to localised blast loading
【24h】

Experimental response of S2-glass fibre reinforced composites subjected to localised blast loading

机译:S2-玻璃纤维增​​强复合材料在局部爆炸载荷作用下的实验响应

获取原文

摘要

A series of localised blast experiments were conducted at two standoff distances (SODs) using cylindrical charges of plastic explosive to study the response of S2-Glass/SC1008 phenolic fibre reinforced polymer (FRP) composite. Digital image correlation (DIC) was used to determine the transient deflection of the composite. The rupture thresholds at SODs of 50 mm and 25 mm, were determined to be 72.5 g and 32.5 g, respectively. Fibre rupture was found to be the dominant damage mode at the centre of panels with delamination and local buckling present at other locations. The response of this composite material was compared with three armour grade steels, a high strength industrial steel and two composite materials that were previously tested using similar loading conditions. The results indicated that the S2-Glass phenolic FRP performed well in comparison to the previously evaluated composite materials. However, the rupture threshold of the S2-Glass FRP was significantly lower than the various grades of armour steel of the same areal density.
机译:使用塑料炸药的圆柱形装药,在两个间隔距离(SOD)上进行了一系列局部爆炸实验,以研究S2-Glass / SC1008酚醛纤维增强聚合物(FRP)复合材料的响应。数字图像相关性(DIC)用于确定复合材料的瞬态偏转。在50 mm和25 mm的SOD处的破裂阈值分别确定为72.5 g和32.5 g。发现纤维破裂是面板中央的主要损坏方式,在其他位置存在分层和局部屈曲。将该复合材料的响应与三种装甲级钢,一种高强度工业用钢和两种复合材料进行了比较,这些复合材料先前已在相似的负载条件下进行了测试。结果表明,与先前评估的复合材料相比,S2-玻璃酚FRP表现良好。但是,S2-玻璃纤维增​​强塑料的断裂阈值明显低于相同面密度的各种等级的铠装钢。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号