A study into the effectiveness of rebar treated with an oil-based corrosion inhibiting spray (Q30 and B'Laster Corrosion Stop) Samples were placed in a simulated sea water bath and monitoring the corrosion or degree of lack thereof via mass and resistivity measurements for a period of time. It was concluded that oil-based spray coating for this application, isn't suitable, due to the feasibility effects of per-coat drying time - with repeated coating being imperative, compromising of coat performance through handling, the 'non-drying' nature of coats which would affect concrete bonding ability. Cold Dynamic Spray Treatment will only be presented theoretically and results will be presented as a follow up to this conference paper.
机译:对用油基缓蚀剂(Q30和B'Laster腐蚀停止剂)处理的钢筋的有效性进行的研究将样品置于模拟海水浴中,并通过质量和电阻率测量来监测其腐蚀或缺乏程度一段的时间。结论是,由于每涂层干燥时间的可行性影响,油基喷涂不适用于此应用-重复涂层是必不可少的,通过处理损害了涂层性能,“不干燥”性质会影响混凝土粘结能力的涂料。冷态动态喷雾处理仅在理论上进行介绍,其结果将作为本会议论文的后续内容。