首页> 外文会议>International Conference on Solid-State Sensors, Actuators and Microsystems & Eurosensors XXXIII >A Novel Cortisol Biosensor Based on the Capacitive Structure of Hafnium Oxide: Application for Heart Failure Monitoring
【24h】

A Novel Cortisol Biosensor Based on the Capacitive Structure of Hafnium Oxide: Application for Heart Failure Monitoring

机译:基于氧化Ha电容结构的新型皮质醇生物传感器:在心力衰竭监测中的应用

获取原文

摘要

) was accomplished. In this context, the interaction between the cortisol with its corresponding polyclonal antibody (pAb) has been studied, and the detection event was followed by electrochemical impedance spectroscopy (EIS). Cortisol was detectable between a wide range of concentration from 2 ng/mL to 50 ng/mL. Moreover, the cross-selectivity study showed that the developed biosensor demonstrated to be highly selective toward cortisol when compared to some related biomarkers such as Tumor Necrosis Factor (TNF-) and N-terminal pro B-type Natriuretic Peptide (NT-proBNP). To the best of our knowledge, this is the first biosensor that has been based on capacitive HfO
机译:)完成。在这种情况下,研究了皮质醇与其相应的多克隆抗体(pAb)之间的相互作用,并通过电化学阻抗谱(EIS)跟踪了检测事件。在从2 ng / mL到50 ng / mL的宽浓度范围内都可以检测到皮质醇。此外,交叉选择性研究表明,与一些相关的生物标志物,例如肿瘤坏死因子(TNF-α)和N端pro B型利钠肽(NT-proBNP)相比,开发的生物传感器对皮质醇具有高度选择性。 。据我们所知,这是第一个基于电容性HfO的生物传感器