The electric supply industry has been undergoing drastic change right from 1980's. A significant feature of these changes is to create competition. The minor portion of the cost is governed by the transmission cost but creates a large impact over the Indian power market. It should be ensured that the transaction charges should be paid by users must be fair and accurate. In India MW mile is frequently used for pricing the transmission services. This method does not consider transmission losses and power factor of the load while calculating transaction cost. This paper presents you how transmission losses and power factor of the load affects the transmission charges by a case study of IEEE 30 bus system using MW mile method. This paper presents you the comparison of the transmission cost by incorporating transmission losses considering power factor with the cost without considering the transmission loss and power factor. It is necessary that the benefit of power factor improvement at the load end must be given to the user. This will encourage the users to operate their system at optimal power factor for receiving benefits. Users have to pay the penalty for poor power factor. Therefore this paper have included the transmission losses along with the term associated with the variation in the load power factor from the power factor set by the regulator in pricing the transmission services. Newton Raphson method is used to calculate the line flows and losses in an IEEE 30 bus system due to each transaction of power and finally cost is calculated using mw mile method after including losses and the power factor correction term.
机译:从1980年代开始,供电行业就发生了翻天覆地的变化。这些变化的一个重要特征是创造竞争。成本的一小部分由输电成本控制,但对印度电力市场产生了很大影响。应确保用户应支付的交易费用必须公平准确。在印度,兆瓦英里通常用于定价传输服务。该方法在计算交易成本时未考虑传输损耗和负载的功率因数。本文通过使用MW mile方法的IEEE 30总线系统案例研究,向您介绍负载的传输损耗和功率因数如何影响传输电荷。本文通过将考虑功率因数的传输损耗与不考虑传输损耗和功率因数的成本相结合,为您提供传输成本的比较。必须将负载端功率因数改善的好处提供给用户。这将鼓励用户以最佳功率因数运行其系统,以获得收益。用户必须为功率因数不佳支付罚款。因此,本文将传输损耗以及与负载功率因数的变化相关的术语包括在内,该术语与调节器在定价传输服务时设置的功率因数有关。牛顿拉夫森法用于计算由于每次功率交易而在IEEE 30总线系统中的线路流量和损耗,最后在扣除损耗和功率因数校正项后,使用mw mile方法计算成本。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号