Three sets of 100MVar STATCOM devices have been installed within the Funing converter station to solve the problem of dynamic reactive power insufficiency of weak system in ±500kV Yong-Fu HVDC Project. In this paper, the reverse control during AC filter putting into operation and the transient supporting action during the AC transient fault recovery are analyzed, and the control strategy and response characteristics are described in detail. The data of STATCOM design research and field test are collated, and verify the characteristics of STATCOM, with tripping event caused by artificial AC short circuit test, analyze the causes of transient locking and fault exit in STATCOM. This paper reveals the operation characteristics of large capacity STATCOM device in DC converter station, through the coordination of STATCOM and transient control, the risk of DC commutation failure and disturbance can be reduced and the optimization measures of STATCOM control strategy are put forward. By studying the response characteristics of STATCOM in the converter station, it is proved that three sets of STATCOM can support the steady operation of DC system.
机译:阜宁换流站内已安装三套100MVar STATCOM装置,以解决±500kV永福高压直流输电工程弱系统动态无功不足的问题。本文分析了交流滤波器投入运行时的反向控制以及交流暂态故障恢复过程中的暂态支持作用,并详细描述了其控制策略和响应特性。对STATCOM设计研究和现场测试的数据进行整理,验证STATCOM的特性,以人为交流短路测试引起的跳闸事件为例,分析STATCOM瞬态锁定和故障退出的原因。揭示了直流换流站大容量STATCOM装置的工作特性,通过STATCOM与暂态控制的配合,可以降低直流换相失败和干扰的风险,并提出了STATCOM控制策略的优化措施。通过研究换流站STATCOM的响应特性,证明三套STATCOM可以支持直流系统的稳定运行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号