首页> 外文会议>International Conference on Power System Technology >Harmonic Responsibility Division Method for Microgrid
【24h】

Harmonic Responsibility Division Method for Microgrid

机译:微电网谐波责任划分方法

获取原文

摘要

Heavy-permeability power electronics make the harmonic sources more complex in microgrid. In order to accurately evaluate the issue of harmonic responsibility generated by distributed generations and individual customers, this paper proposes a method of harmonic responsibility division based on ideal load current. There are two indices named ideal load current and the non-ideal load current are defined according to the ideal load characteristics. Depending on the harmonic voltage propagation characteristics of distributed generation and non-linear load, the ideal load parameters of microgrid are calculated by analyzing multiple harmonic source equivalent networks of microgrid from the perspective of individual customers, and the harmonic current generated by background harmonic voltage is decoupled from the ideal load current under the condition of deterioration of the voltage waveform, and the load harmonic current is decoupled from the non-ideal load current to realize the harmonic responsibility division of the microgrid. The proposed method does not need to calculate the network structure and system impedance information. Several cases of simulation analysis prove the validity and rationality of this method.
机译:高磁导率电力电子设备使微电网中的谐波源更加复杂。为了准确评估分布式发电和个人用户产生的谐波责任问题,提出了一种基于理想负载电流的谐波责任分配方法。有两个指标分别称为理想负载电流和非理想负载电流,这是根据理想负载特性定义的。根据分布式发电和非线性负荷的谐波电压传播特性,通过从单个用户的角度分析微电网的多个谐波源等效网络,计算出微电网的理想负荷参数,背景谐波电压产生的谐波电流为在电压波形恶化的情况下与理想负载电流解耦,将负载谐波电流与非理想负载电流解耦,实现微电网的谐波责任分配。所提出的方法不需要计算网络结构和系统阻抗信息。仿真分析的若干情况证明了该方法的有效性和合理性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号