is 800 K, 800 K, 750 K and 850 K at 0.22 THz, 0.55 THz, 0.85 THz and 1.44 THz respectively. The optimal bias voltage seems independent to the frequency and bath temperature. The bath-temperature dependence of noise temperature has also been investigated, the bath temperature has limited effect on the noise temperature when it is operated below its transition temperature. A similar frequency response of corrected mixer noise temperature has been observed at 4 K and 7 K bath temperature, which indicates the RF coupling efficiency of planar spiral antenna of HEB mixer.
机译:分别为0.22 THz,0.55 THz,0.85 THz和1.44 THz时的800 K,800 K,750 K和850K。最佳偏置电压似乎与频率和熔池温度无关。还研究了噪声温度对浴温的依赖性,当浴温低于其转变温度时,浴温对噪声温度的影响有限。校正混频器噪声温度在4 K和7 K浴温下具有相似的频率响应,这表明HEB混频器的平面螺旋天线的RF耦合效率。