首页> 外文会议>International Conference on Engineering Simulation and Intelligent Control >Local Analysis of Main Tower in a Single Pylon Cable-Stayed Bridge
【24h】

Local Analysis of Main Tower in a Single Pylon Cable-Stayed Bridge

机译:单塔斜拉桥主塔局部分析

获取原文

摘要

The main tower as the main load-bearing component of cable-stayed bridges, its safety has the crucial importance. Since the overall calculation of the bridge structure can not fully reflect the internal force of the key parts of the main tower, it is necessary to conduct the local calculation of the complex stress area of the main tower. In this paper, a 2×132m single tower cable-stayed bridge in Shaanxi Province is taken as an example, using Midas / civil software to analyze the main tower bifurcation section and the tower girder consolidation section. In order to comprehensively improve the calculation accuracy and computation efficiency, a multi-scale modeling method is applied in this paper. The calculation results show that the stress of the main tower bifurcation section is complex and the section should be modified. Also the stress of the consolidation section of the tower and girder satisfies the requirements of the code.
机译:主塔作为斜拉桥的主要承重构件,其安全性至关重要。由于桥梁结构的整体计算不能完全反映主塔关键部位的内力,因此有必要对主塔的复杂应力区域进行局部计算。本文以陕西省某2×132m单塔斜拉桥为例,利用Midas / Civil软件对主塔分叉段和塔梁固结段进行分析。为了全面提高计算精度和计算效率,本文采用了多尺度建模方法。计算结果表明,主塔分叉段的应力较为复杂,需要对该段进行修改。塔和大梁固结部分的应力也满足规范的要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号