首页> 外文会议>International Conference on Diagnostics in Electrical Engineering >Changes of loss factor of polypropylene film capacitors during long time thermal ageing
【24h】

Changes of loss factor of polypropylene film capacitors during long time thermal ageing

机译:长时间热老化过程中聚丙烯薄膜电容器损耗因子的变化

获取原文

摘要

Polypropylene film capacitors are high-quality electronic components used in many applications. PP capacitors are only available as leaded components, have a self-healing ability and low loss factor. The work was oriented on study of percentage changes of the loss factor of PP film capacitors during long-time thermal treatment at the temperature of 100 °C. The capacitance of measured samples was 0.1 μF, class of the capacitors was X2. Products of five manufacturers were tested. Measurements were carried out using an RLC measuring device HP4284A. The percentage changes in the loss factor measured at the 1 kHz, 10 kHz, 100 kHz and 1 MHz frequencies due to thermal treatment for 20,000 hours were inspected. It was found that the changes are in the range of 1.4 to 3 % and that the changes only slightly depend on the value of the loss factor of the capacitors at the beginning of the test.
机译:聚丙烯薄膜电容器是许多应用中使用的高质量电子组件。 PP电容器仅可作为含铅组件使用,具有自愈能力和低损耗因数。这项工作的重点是研究在100°C的温度下长时间热处理期间PP薄膜电容器损耗因子的百分比变化。被测样品的电容为0.1μF,电容器类别为X2。测试了五个制造商的产品。使用RLC测量装置HP4284A进行测量。检查了由于热处理20,000小时而在1 kHz,10 kHz,100 kHz和1 MHz频率下测得的损耗因子的百分比变化。已经发现,该变化在1.4%至3%的范围内,并且该变化仅在很小程度上取决于测试开始时电容器的损耗因子的值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号