Dielectric loss angle is a very important parameter to evaluate the insulation condition of capacitive devices, which is the complement angle of voltage and leakage current. The angle value is hard to accurately obtained because of field interferences and other causes. The leakage current is so small which the signal path parameters and other interference contribute a fairly large error. In this paper, an equivalent circuit model of capacitive equipment considering multicomponent parameters is established. By analyzing the influence of electromagnetic field distribution and wiring modes on the leakage current path, an equivalent circuit model considering many influencing factors is proposed. This paper also analyzes the influence of aging, temperature and humidity on the equivalent circuit parameters, explores the causes of the current measurement error, and finally obtains the transfer function of the leakage current and the path component parameters.
机译:介电损耗角是评估电容器件绝缘状况的非常重要的参数,它是电压和漏电流的补角。由于场干扰和其他原因,难以精确地获得角度值。泄漏电流非常小,信号路径参数和其他干扰会造成相当大的误差。本文建立了考虑多分量参数的电容设备等效电路模型。通过分析电磁场分布和布线方式对泄漏电流路径的影响,提出了一种考虑多种影响因素的等效电路模型。本文还分析了老化,温度和湿度对等效电路参数的影响,探讨了电流测量误差的原因,最后获得了泄漏电流的传递函数和路径分量参数。