首页> 外文会议>International Conference on Computer and Communication Engineering >Impact of Cable Bleeding into RLCG of Twisted Pair Copper Cable and Achievable Bit Rate
【24h】

Impact of Cable Bleeding into RLCG of Twisted Pair Copper Cable and Achievable Bit Rate

机译:双绞铜线电缆渗入RLCG的影响及可达到的比特率

获取原文

摘要

This paper we are actually investigating the impact of cable bleeding into RLCG twisted pair and achievable bit rate based on VDSL2 profiles (17a). The study has been done by carried out investigation on attenuation copper cable itself in ideal conditions and cable bleeding. S-parameter for ideal conditions with distances in 100m, 200m and 300m is obtained. Besides that, the copper cable 200m has been tested in non-ideal conditions when it is bleeding conditions defined by 0. 3cm lengths of bleed. It is observed that at 18MHz the attenuation is increases while the increases of cable distance. Then, from S- parameter results it can been analyzed into RLCG model which is can represents into lumped-element circuit and also the performances maximum achievable bit rate. It is found significant effect on the cable bleeding for 200m with it performances in attenuation and achievable bit rate compared to ideal conditions.
机译:本文我们实际上是在研究基于VDSL2规范(17a)的电缆渗入RLCG双绞线和可达到的比特率的影响。该研究是通过对理想条件下的衰减铜电缆本身和电缆渗漏进行调查而完成的。获得距离为100m,200m和300m的理想条件下的S参数。除此之外,当铜缆200m处于由0. 3cm长度的出血所限定的渗出条件时,已经在非理想条件下进行了测试。可以看出,在18MHz处,衰减增加,而电缆距离增加。然后,根据S参数结果,可以将其分析为RLCG模型,该模型可以表示为集总元件电路,并且还可以实现最大可达到的比特率性能。与理想条件相比,它在衰减和可达到的比特率方面表现出对200m电缆渗漏的显着影响。