首页> 外文会议>Intelligent System Design and Engineering Application (ISDEA), 2012 Second International Conference on >Pre-treatment of High-Strength Acid Dye Wastewater with Internal electrolysis-Fenton Process
【24h】

Pre-treatment of High-Strength Acid Dye Wastewater with Internal electrolysis-Fenton Process

机译:内电解-Fenton法预处理高浓度酸性染料废水

获取原文
获取原文并翻译 | 示例

摘要

It was studied that the performance of the internal electrolysis-Fenton process in pre-treating of the high-strength refractory acid dye wastewater. The sequencing comparative experiments were carried out and it was determined that the internal electrolysis-Fenton process was superior to the traditional one in terms of treatment effect. Optimal conditions were attained by experimental conditions changing. The results show that under optimal conditions pH=2, the volume ratio of Fe/GAC is 1 and the reaction time is 30 min. The dosage of H2O2 is 40/00 by continuously dosing, its pH is 3 and the reaction time 30 min. the COD removal rate could be more than 75% and the BOD5/COD ratio could be increased from 0.08 to 0.46. This process showed highly efficient in organic removal and biodegradability improving in pre-treating high-strength dye wastewater.
机译:研究了内部电解-芬顿法在高强度耐火酸性染料废水预处理中的性能。进行了测序比较实验,确定了内部电解-芬顿法在处理效果方面优于传统方法。通过改变实验条件可以达到最佳条件。结果表明,在最佳条件下pH = 2,Fe / GAC的体积比为1,反应时间为30 min。连续投加H 2 O 2 的剂量为4 0 / 00 ,其pH为3,反应时间30分钟。 COD去除率可以达到75%以上,BOD 5 / COD比可以从0.08提高到0.46。该方法在预处理高强度染料废水中显示出高效的有机去除和生物降解性改善。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号